Tender For bid to ras providing of repair and overhauling service - repair of ground power unit 40 kva (gpu 40 kva); repair of ground power unit 40 kva (gpu 40 kva); yes; service provider premises
Tender For bid to ras repair, maintenance, and installation of plant/ systems/equipments (version 2); contract for network arc of trombay unit- 1 12 core single mode outdoor fibre optic cable of 9/125 micron specification, make:, link/ digilink/ molex/ tyco /amp/ systimax/ r&m/ panduit/ rit or equivalent, mtr 3000, 2 24 core single mode outdoor fibre optic cable of 9/125 micron specification, make:, link/ digilink/ molex/ tyco /amp/ systimax/ r&m/ panduit/ rit or equivalent, no 2000, 3 lc-sc single mode 9/125 duplex fibre patch cord of minimum 2 meter length, make:, dlink/ digilink/molex/tyco/amp/systimax/r&m/panduit or equivalent, no 50, 4 utp cat 5e cable ( 300 meter box), make: dlink/ digilink/ tyco/ amp/ systimax/, r&m/panduit/rit or equivalent, no 70, 5 modular type cat 5e wall mount information outlet with one rj 45 port and box,, make: dlink/digilink/tyco/ amp/systimax/ r&m/ panduit /rit or equivalent, no 1000, 6 cat 5e rj 45 jacks (1 box of 100 nos. connectors), make: dlink/digilink /molex/tyco, /amp/ systimax/ r&m/ panduit/rit or equivalent, no 50, 7 utp cat 6 cable ( 300 meter box), make: dlink/digilink /molex/tyco /amp /systimax/, r&m/panduit/rit or equivalent, no 20, 8 1 inch pvc casing caping 1 conduit, t -joint accessories, couplers etc. for fixing, isi, make, mtr 1000, 9 6 u wall mount rack with fans & power adapter strip, front & both side door, openings, make: valrack/netrack/srlink or equivalent, no 10, 10 9 u wall mount rack with fans & power adapter strip, front & both side door, openings, make: valrack/netrack/srlink or equivalent, no 10, 11 outdoor water proof underground enclosure box for ofc splicing of 24 core splicing,, make: raycaum / mx or equivalent, no 100, 12 wifi extender repeater signal booster, 300mbps make: dlink or equivalent no 20, sr item description in supply uom estimated, qty, 13 underground digging 2 feet deep in soft soil, backfilling for restoration to original, state, mtr 4000, 14 underground digging 2 feet deep in hard soil, & backfilling for restoration to original, state, mtr 1000, 15 underground digging 2 feet deep in tar road & backfilling for restoration to original, state, mtr 500, 16 underground digging 2 feet deep in concrete & backfilling for restoration to original, state, mtr 500, 17 pulling of fo cables inside duct and laying in underground trench mtr 5000, 18 pulling of fo cables inside casing caping / conduits and saddling inside building mtr 3000, 19 pulling of utp cables inside duct and laying in underground trench mtr 2000, 20 pulling of utp cables inside casing caping / conduits and saddling inside building mtr 15000, 21 pulling of fo cables / utp cables inside duct and laying on existing cable tray of 15, feet hight from ground using scaffolding / articulate booms, mtr 3000, 22 termination of utp cat 5/6 cable in rj45 information outlet (i/o) / jacks, fixing of i/o, box on wall, no 2000, 23 otdr testing for fo cable core no 1000, 24 splicing of sm / mm fo cable cores in liu / enclosure box & dressing no 5000, 25 installation / mounting of 6u / 9u rack on wall no 25, 26 one no onsite manpower qtr 12.
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; tender for the job of obtaining consent to establish for hter scheme at rcf thal unit through nipl route; as per scope of work; a) safety violation by contractor employee at work place: 1) working without wearing safety helmet (per person), 2) working without wearing safety shoes (per person), 3) working without wearing safety goggle &/or hand gloves during handling of hazardous chemicals, acid/alkali etc. (per person), 4) working without wearing safety belt (double lanyard full body harness) for height jobs above 2 meters. (per person), 5) working without wearing face shield during cutting, welding, grinding activity and during maintenance work on process lines and equipment. (per person), 6) not using ppe, tools/tackles as mentioned in safety work permit (per person), 7) working without valid test certificate for lifting tools/tackles (per incidence observation), 8) working without appropriate electric plug-pin, elcb/rccb/rcbo (per incidence observation), 9) working without a valid safety work permit (per incidence/ observation), 10) permit not available at site (per incidence/observation), 11) gas cylinder without flash back arrestor (per incidence observation), 12) gas cutting set with damaged hose pressure gauge without valve key (per incidence/observation), 13) gas cylinder without trolley (filled and empty) (per incidence/ observation), 14) unauthorized personal entering into cordon off area (per incidence/observation), 15) faulty wire/cable laying on ground or using snapped cables (per incidence/observation)., 16) improper hand tool or power tools (per incidence observation), 17) smoking at work place area. (per person), 18) found in intoxicated state (per person), 19) violation of road rules (per incidence observation), 20) b) safety violations by transport contractors, 21) faulty hazchem displayed on tanker (per incidence observation), 22) one pvc/tychem suit set if available (per incidence/ observation), 23) both pvc/tychem suit set are not available (per incidence observation), 24) fire extinguisher without hydro test. (per incidence/ observation), 25) trem card not available (per incidence/observation), 26) hazardous chemicals transportation training of driver by authorized agencies. (training card not available with driver) (per person), 27) lying/resting below the vehicle(per incidence/observation), 28) any other deviation found as per checklist for tankers (per incidence/ observation.
Tender For auction sale of depot ferrous scrap - 12112ms26b, 98050011, quantity- 79.435 mts. scrap condemned unserviceable ms-ci signal interlocking materials consisting of levers, rods, ms campus rollers of molb, molb weights, molb booms, signal tubular post, roller trestle, stop boards, 33 mm rods, signal arms, gi and ms wires, lc gate pipes, gate structures, ladders, angles, channels, joists, roller stands, electric poles, cable termination box, direct type lever frame, sa 1914 type trays, sm slides, ssi termination rack, control panels, signal booms, boom locks, cable termination rack, adjustable crank, e type lock, cable marker, ground connection rods, fuse unit, power racks, cam path, gear box, signal reverser, ground lever frame, molb, eolb pedestal, telecom charger body, wire adjustment screws, molb compass roller, gate weights, cls tubular post, surface base, nuts, bolts, rounds, turnout wheels, eye joints, point machine covers, clamps, signal buckets, pulleys, d.w.diversion wheel, gate control panel, calling on unit, gear box assembly with clutch, winch, offset brackets, h.p lock, chequered plates, ptb, location boxes, rkt, axle counter coil fixing plate, shunt signals, route arm, route [1 way, 2 way, 3 way and 4 way], ib hut cut parts, ms electrical point detector, junction type route indicator, route indicators, structures, casing structures, ci bases, gear wheels, flats, cable termination base, u- brackets, ci weights of booms, fabricated posts, cls 2, 3 and 4 aspect units, trestle, sge block instrument, y-crank, stands for wheel tension measuring devices of d.w clutch, lock bar clips, drum clock, ec boxes, relay racks, tlj boxes, foundation shoe, ekt, pd clamps, galaxy stand, meeting posts, signal lamp structures, point rods and other similar signal and interlocking scrap material of sorts and sizes, with or without attachments including negligible nf attachments. note- nf attachments are approximately 2 percent of lot quantity. location- bin no- 112, right side of road no- 1. hsn code- 72044900. gst- 18 percent note: private crane permitted for loading purpose. note- delivery on actual weighment basis only. special note: overload of the carrying capacity of the vehicle will not be permitted at the time of taking delivery as per motor vehicle act 1988.
Tender For auction sale of depot ferrous scrap - scrap and unserviceable condemned mix m.s. coach cutting items & various types of similar items such as , body side door m.s., p.o.h. coaches realised corroded pieces,air brake,clamp,pipe pin,m.s. door of battery box ,m.s.ventilation door,foot plate,ice box,m.s. spring,m.s. angle,and m.s. lader with rubber coating,coach cuttings, coach doors , seat frames , bearth/seat frames, light head stock cuttings, train lighting fittings,, side lamps lamp hand signal, fittings, tail lamp fittings, cft/tl light fittings, ictp/ icfp empty swich boxes tail lamps, tube light fittings, tube light jali, fan blades, fan jali, fan guards fan ribs, fan rings, empty power pannels, signal platform, destination board, valley board, letter board,ms signal base, loc, inercooler, nut bolts and other hardwares, m s furniture.m s wheel stand,window grill, ms measuring cans, tins, racks, break pipes, silencer of tower wagon, dust bin, ms pipe and cut pcs. of ms pipes, rods, ms bars released from broken constructin, compressor spring, wire /coil springs, ms rope wire, pcs. of brake beam pipes, stands, m s ferrous light junk kachra related scrap i.e ms angles, chanels, flats pcs. of cable racks/laders ms brackets, dust bin stand, tin fuse box, fire extinguisher, empty glow sign boards, empty electrical pannel, ms stand, oven, earthing patti, empty cable tray, fly catcher, galvanized patra / sheet and their cut offs, cut pieces of ms cupboards, rack etc, plain/ corrugated / toughened sheets and its cut pcs. such as strips, patties, patties, patra, rings, coils, boxes, ms brake control cover, patra, angle, small springs, pins, wire, electric point, shunt signal unit and post. signal ladder , location box, earth electrode , signal post and base , signal unit, point roddings , junction route indicator and cut pieces in mijscellaneous, coil, collapsible doors and shutters and their parts/cut offs, grills , channel grills, compound /bridge jali with or without frame, ms fencing and their parts, fencing patties, angle pcs., frames,wire mesh, g.i./ms pipes and tubes , tubes and their cut pcs, damaged gi/ ms pipes/ rods/tubes and their pcs. , ms/galvanised boxes, junction box, switch boxes, empty convertor, payary (steps), filters, rings, nut bolts, u clips, pipe pin, gate m/c dismentled, liquid container, damaged video boxes and their cut offs, crt cabinet, location boxes , jumper, jumper box,ground connections , basket steel, water cane/ material carring trolley,steel baskets, containers, trays, frames, stretchers, nets/ jali , released ground connection, halogen, panto pans, compressor spares, dust guard, air filters and filter covers, ms/gi duct and its parts,insulating armature of signal cable, hand lamps, side lamps, signal lamps petromax, hs lamp, clamps, signal post,signal platform, signal base, ms/ gi wire/ coil, funnels, wall protectors, boxes, iron bar pcs released from broken construction , desmantelled weighing machines parts/ covers etc. ms pipe with or without ci attachment, bins, plates, rings, spares/ parts /body of weighing machine , platform weighing machine and its parts, pressure switches and other switches , signal parts, location boxes,panel board,fuse box,mdb board,pedestial for lc gate and their cut parts and other ferrous miscellaneous scrap items with or without minor nf/ss/ wooden / rubber / rexine attachments of sorts and sizes, broken and damaged, u/s for rly. use, excluding items: rail and rail pcs., axles and axle pcs., wheel tyre and pcs., cam shafts, helical springs, bolster springs, buffer plungers, face plates, axle box housings/ casings, brake beams, fish plates, screw couplings/draw bar hooks, break beams, reservoir tanks, st sleepers and other various types of similar ms items etc. note: 1. hammering/ pressing/ cutting is permitted for easy loading only, 2. if found any non-ferrous item will not be delivered (qty approx
Tender For supply of kay make rotary twin lobe compressor mm 65ac its spares for ccd d d -rotary twin lobe compressor, speed: 1200 rpm, capacity: 300 m3/hr, pressure rating: 0.2 kg/cm2, motor power rating: 5 hp, power output: 3.7 bhp, motor: 945 rpm, for unit 900 of ccd-iii, scope of supply:common base frame, suction filter, safety valve, v-belts, v-belt guard, suction silencer, discharge silencer, nrv, pressure gauge, all fixing nuts and bolts, drive and driven pulleys, interconnecting piping, set of foundation bolts, anti-vibration pads (without motor), moc-casing: c.i.f.g. 260, is:210, lobe c.i.f.g.260, is:210, shaft:(en-19t), bs:970, gears, sae8620/805m 20 (bs: 970) (hardened and ground), bearings: skf/equivalent.